100.0TB - 240TB RAID combines SAS and SATA-II 6.0Gb/s
and 12.0Gb/s storage technologies with 3.4GB/sec.4xiSCSI Channel SAN host interface to data protection RAID 6 in a
4U rack-optimized enclosure.
The innovative GVS-designed Nomadic 4U RAID architecture combines affordable, high-capacity 6GB SAS and SATA-II/III drive technology with a quad iSCSI channel host interface per hardware RAID controller, reliable data access. Each GVS Drive Module uses
a dedicated 6.0Gb/s SAS or SATA drive channel, maximizing the Gigabit/s Per Channel host connection.
4280i Controller RAID features:
RAID level 0, 1, 1E, 3, 5, 6, 10, 30, 50, 60,100 Single Disk or JBOD
Multiple RAID selection
12(8) independent logical arrays configurations per controller
Online array roaming
Offline RAID set
Online RAID level/stripe size migration
Online volume set growth
Support global hot spare and dedicated hot spare
Instant availability and background initialization
Automatic drive insertion / removal detection and rebuilding
Greater than 2TB per volume set (64-bit LBA support)
Greater than 2TB per disk drive
Each logical array can have an independent
RAID level
Write back and write through cache selection
Variable stripe size
LUN slicing
Online RAID group capacity expansion
Drive hot-swapping
Intelligent Drive Management
Battery backup support
Disk scrubbing/ array verify scheduling for automatic repair of all configured RAID sets
Login record in the event log with IP address and service (http, telnet and serial)
Support intelligent power management to save energy and extend service life
Support NTP protocol to synchronize RAID controller clock over the on-board LAN port
Redundant controller operation with active/active and failover/failback function
Dual-active RAID controller with cache mirroring through dedicated high speed bus
Automatic synchronization of firmware version in the dual-active mode
Multi-path & load-balancing support (Microsoft MPIO)
Support for multiple RAID sets, multiple hosts and LUN masking and mapping
Max 122 devices
Max 128 LUNs (volume set) per controller
Management:
GVS View management software for all major platforms via Ethernet port
Event notification via an independent
GVSView client utility
Field-upgradeable firmware in flash ROM
Firmware-embedded manager via RS-232 port
Firmware-embedded Web Browser-based RAID manager - Access your RAID subsystem from any standard internet browser via 10/100 Lan port
Firmware-embedded SMTP manager monitors all system events and user can select either single or multiple user notifications to be sent via e-mails
Firmware-embedded SNMP agent allows remote to monitor events via 10/100/1000 LAN with no SNMP agent required Access terminal menu by telnet via 10/100/1000 LAN port API library for customer to write its own monitor utility SAP management feature to easily manage multiple RAID units in the network
|
Host Interface to the iSCSI storage:
Four, Gbite iSCS Channel ports (RJ45), Gigabit/s throughput per channel
Guaranteed delivery (full duplex) per channel max block level access.
Access to Nomadic 4U via direct, or SAN setup to single or moultip host with thred-party iSCSI client support.
1000BASE-T Ethernet for remote management
Support read/write per port or read only through
iSCSI Channel port without the need for SAN Software or switch
Short-Haul Transceiver (supports up to 500m with 50/125 m MMF)
Long-Haul Transceiver (supports up to 10km with 9/125 m SMF)
Host Interface to the iSCSI SAN storage:
4xGBit ports (RJ45)
Guaranteed delivery (GB/sec. full duplex) per channel max 8GB/sec.
4xGBit/sec Channel
RAID level 0,1,0+1,3,5,6,10,30,50, 60, 100 JBOD, N-way mirror
Up to 2048 logical volumes
Up to 64 hard drives per RAID group
One logic volume can be shared by as many as 16 hosts
Global and dedicated hot spare
Write-through or write-back cache policy
Online volume expansion
Instant RAID volume availability
Auto volume rebuilding
On-line volume migration without system down time
RAID Controller specifications:
2GB cache per controller up to for 4xGB Channel Host Interface
SAS Channel Interface Optional:
Provide 2 16GB port connects to SAS to high speed RAID storage w/SAS client access to the server with dual 16GB SAS port option.
SAS Expansion Interface:
24 drive per single Nomadic4U expansion bay
Battery Backup Module:
Smart battery backup module, integrated lithium cells. With one fully charged battery module used for each cached data protection during power failure .
Material:
Heavy-duty cold-rolled steel
Inside:
Zinc-plated with bright chromate
Outside:
Top cover anodized for better cooling
Cooling:
Rear: 4 x 60x 38mm hot-swap fans
Self-regulating speeds and front-to-back cooling
Optional: Front security door locking, noise reduction and air filter
Expansion:
24 hotswap SAS/SATA-II drive bay with up to
4 x RJ45 Interface, iSCSI and 2xSAS expansion 128 drive support per single SAS expansion port
Controls:
Power secure lock key for on/off and system
reset + USB + serial port + RJ45 + 4 RJ45 + SATA and SAS Drive host interface with 6GB SAS expansion port |
8GB Total Channel Host Interface Options Single or Dual Controller:
iSCSI Channel hardware offload engine support
Auto detect speed and topology, Topology support : Point-to-point, Fabric
Role-based access control / Active directory
Up to 64 multiple nodes support
Up to 64 hosts support
Up to 512 sessions per controller
Dual Controller Options for GBit Channel Host Interface
Dual-Active RAID controllers
Cache mirroring through high bandwidth channels (NTB)
Flexible RAID group ownership management
Management port seamless take-over
Online firmware upgrade, no system down time (dual-controller mode only)
Multi-path & load-balancing support (Microsoft MPIO, MC/S, Trucking, LACP)
Advanced Data Protection for 16GB Fibre:
Replica remote replication
Snap writable snapshot
Volume cloning Microsoft Windows Volume Shadow Copy Services (VSS)
Configured N-way mirror
Online disk roaming
Instant volume restoration
Hot plug gable battery backup module (BBM, 72 hours for 16GB RAM)
Network UPS
OS Support:
Windows, Windows Server
Red Hat Enterprise Linux
Mac OS
Indicators:
Power, LAN, 4xiSCSI Channel, Drive, eSAS, RS232, and Host
Virtualization:
VMware (VAAI); Citrix; Hyper-V
Drive Bay:
Hotswap 24x SAS/SATA-II (SATA 6G)
Optional SAS and SATA Drive Bay mix
Temperature:
5°C to 35°C (41°F to 95°F)
Storage temperature: -40° to 47°C (-40°F to
140°F)
Humidity:
Operation mode : 20% to 80%
non-condensing
Altitude:
Sea level to 10,000 ft.
Maximum thermal output: 1465 BTUs per hour
Power Supply Nomadic4U:
2x1,000W hot-swap Redundant load-sharing hot-swap power supplies
Min. 1x1000W module w/ 24 Drive and Dual Controller support
Each 1000W Module run Max 40A
Max 3x Universal input (100V to 230V AC),
power factor corrected
Frequency: 47Hz to 63Hz, single phase 8-4A
Power Consumption Nomadic 4U:
Max: 1000W tolerance : ±5% with 24xSATA drive
Max: 705W tolerance : ±5% with 24xSAS drive
Idle: 245W tolerance: ±5%
Dimension Nomadic 4U:
D26” (660.4mm) X W17.58” (446.5) X H7.0” (177.80mm)
With Front Locking Face Option D27.5” (698.5mm) X W17.125” (180.98) X H7.25” (184.15mm)
Weight Nomadic 4U:
70-75 pounds (32-34 kg) hot-swap dual controllers and three power supply |